Fluke i1000s AC Current Probe
|
|
Current Range: 100mA to 1000 Arms
Basic Accuracy 48Hz to 65Hz:
10A Range +/- 3% of reading + 0.1A, 100mV/A output
100A Range +/- 2% of reading + 0.5A, 10mV/A output
1000A Range +/- 1% of reading + 1A, 1mV/A output
Bandwidth: 5Hz to 100kHz
Working Voltage: 600V AC rms
Maximum Conductor Size: 54 mm (2.13 inch) diameter
Safety Rating: 600V rms. CAT III per IEC 1010-02-032
|
Current Clamps
|
|
|
Fluke Priority Gold Instrument CarePlans For Handheld Instruments
|
|
Repairs are always unexpected, and they can be costly. Keep your Fluke Instruments in top operating condition and control your cost of ownership with a Fluke Gold CarePlan. Fluke CarePlans are easy to purchase and register. Maintain your Fluke handheld in peak operating condition and protect your investment beyond your factory warranty. |
CarePlans & warranties
|
|
|
Fluke 80AK-A DMM Thermocouple Adapter
|
|
Adapts Type-K thermocouple mini-connector to dual banana plug inputs
Measurement range and accuracy: probe dependent
Suitable for low voltage applications (below 30 V AC, 60 V DC)
One year warranty
|
Combo Test Kits
|
|
|
Fluke i1010 AC/DC Current Clamp
|
|
Battery-powered dual Hall-effect, clamp-on probe measures dc current from 1-1000A; ac current from 1-600A ac rms
Measures ac and dc current down to 1 amp with specified accuracy and is useable to 0.5A
Output is 1 mV per amp dc or ac
Jaws accept conductor size of 1 X 750 MCM ( 30 mm/1.18 in. diameter) or 2 X 500 MCM (2 X 25 mm/.98 in.)
AC and DC accuracy: ± (2.0% of reading + 0.5A)
|
Current Clamp DMM Accys
|
|
|
Fluke L207 High Intensity Light with Collector's Cap
|
|
Cap adjusts for all-day comfort
Light attaches to bill of baseball cap
Rugged light withstands 6' drops to concrete
Waterproof light case won't crack or chip
Electrically and thermally nonconductive
|
Lights for Probes and Hats
|
|
|
Fluke 324 40/400A AC, 600V AC/DC True-RMS Clamp Meter with Temperature, & Capacitance Measurements
|
|
400 A AC current measurement
600 V AC & DC voltage measurement
True-rms ac voltage and current for accurate measurements on non-linear signals
Resistance measurement up to 40 kΩ with continuity detection
Temperature and capacitance measurement
Features:
Slim, ergonomic design
Backlight display
CAT IV 300V/CAT III 600 V safety rating
Hold button
Two-year warranty
Soft carrying case
|
Current Clamp Meters
|
|
|
Fluke 075-CLV CLV Infrared Window for indoor low-voltage applications
|
|
Industry’s first and only IR Window tested to UL1558 Low Voltage Switchgear Standard
Certified by UL as suitable for Type 1 (Indoor) environment in North America, these windows are tested to withstand the long term aging effects of UV exposure
The Fluke CLIRVU coating—exclusive to Fluke Windows—seals the optic prior to assembly to protect against moisture degradation
For use on enclosures up to 600 V
Identification plate attached for unique, onsite numbering for rapid location... |
Infrared (IR) Windows
|
|
|
Fluke 116 HVAC Multimeter with Temperature and Microamps
|
|
Built in thermometer for HVAC applications
Microamps to test flame sensors
LoZ: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
Resistance, continuity, frequency and capacitance
Min/Max/Average with elapsed time to record signal fluctuations
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger (ToolPak™)
CAT III 600 V safety rated
|
Digital Multimeters
|
|
|
Fluke 2AC/90-1000V VoltAlert AC Non-Contact Voltage Tester
|
|
Voltage detection from 90 to 1000 V ac, suitable for a wide range of residential, commercial and industrial needs
Always on, using special low power circuitry to sustain battery life and ensure your 2AC is always ready.
Innovative ‘Battery Check’ button function ensures battery is in good condition
Category IV – 1000 V overvoltage rated product for best in class user protection
Integrated clip design, optimized for pocket storage
Fluke ruggedness and reliability
Two-year warranty
|
Electrical Testers
|
|
|
Fluke Priority Gold Instrument CarePlans For Handheld Instruments
|
|
Repairs are always unexpected, and they can be costly. Keep your Fluke Instruments in top operating condition and control your cost of ownership with a Fluke Gold CarePlan. Fluke CarePlans are easy to purchase and register. Maintain your Fluke handheld in peak operating condition and protect your investment beyond your factory warranty.
Gold CarePlan features
Includes annual calibration in three days
Offers up to 70% off of factory calibration prices
Free repairs with guaranteed five day... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke 416D 200 ft Laser Distance Meter Discontinued
|
|
Elimination of estimation errors, saving both time and money
The most advanced laser technology for distance measurement
Instant measurement with one-button operation
Easy targeting with bright laser
Quick calculation of area (square footage) and volume
Easy addition and subtraction of measurements
Improved battery life from automatic shut-off feature
Pythagoras calculation
Pouch
Ability to measure up to 60 m (200 feet)
Ability to view more with large, 3-line display with... |
Energy Assessment Kits
|
|
|
Fluke PM9082001 Dual Banana Plug (female) to Male BNC Adapter
|
|
The set consists of two adapters
One red (signal) and one black (ground) 4-mm banana contact
Maximum Signal Voltage: 600V rms
Maximum Voltage to Ground: 600V rms. CAT III per IEC 61010-031
|
Options
|
|
|
Fluke 700P22 Differential Module Wet
|
|
Display pressure readings in any of 10 different pressure units you specify in the calibrator setup
Rugged urethane molded case protects the module from rough handling and harsh conditions
Features internal temperature compensation from 0°C to 50°C for full-accuracy performance
Includes NIST-traceable calibration certificate
Module can be calibrated locally using the Fluke 700PCK Pressure Calibration Kit, a PC, and a precision pressure source
One year warranty
|
Pressure
|
|
|
Fluke 110, 111, 112 Digital Multimeters, Discontinued
|
|
True-rms ac voltage and current for accurate readings on all waveforms
6000 count display provides improved resolution
Min/Max/Average recording
Frequency, capacitance & resistance capabilities
Model 112 has a backlight to illuminate the screen in dark workspaces
Easy access battery door to change the battery without breaking the calibration seal
Drop protected to 1 meter
Holster with probe holders for better test lead management
Compatible with ToolPak™ meter hanging... |
Fuses
|
|
|
Fluke 1630 Earth Ground Clamp Meter
|
|
A wide ground loop resistance range, from 0.025 Ω to1500 Ω, to satisfy all requirements
Large jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus bars
Measurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect - ideal for system troubleshooting
Wide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applications
User-defined HI / LO Alarm limits, for rapid measurement evaluation
Handy... |
Ground Testers
|
|
|
Fluke FVF-SC3
|
|
FlukeView Forms supports the following meters:
Fluke 1550B MegOhmMeter
Fluke 1653 / 1653B Electrical Installation Tester
Fluke 180 series
Fluke 287 and 289
Fluke 45 Fluke 53-II and 54-II
Fluke 568 IR Thermometer
Fluke 789 ProcessMeter
Fluke 8808A
Fluke 8845A/8846A
Fluke 89-IV and 87-IV
Fluke 975 AirMeter Test Tool
Fluke 983 Particle Counter
|
Software
|
|
|
Fluke 884X-1G USB Memory 1 GB
|
|
Used on the 8846A only
Plugs into USB device host port on the 8846A front panel
Fully compliant with Universal Serial Bus Specification v2.0
Dual LED indicates power and busy status
|
Specialty Accessories
|
|
|
Fluke 59 MAX+ -30°C to 500°C Infrared Thermometer
|
|
Precise laser technology makes more accurate and repeatable measurements
Large, easy-to-read backlit LCD display for easy viewing
Small and lightweight design easily fits into your tool box
IP40 rated for extra protection
Displays the minimum, maximum or average temperature, or the difference between two measurements
Hi and Lo alarms for rapid display of measurements outside the limits
Powered by one (1) AA battery
One year warranty
|
Infrared Thermometers
|
|
|
Fluke 80PK-3A Type K Surface Temperature Probe
|
|
For flat or slightly convex surfaces
Ideal for measurement of hot rollers and plates
Measurement range: 0°C to 260°C (32°F to 500°F)
Maximum Temperature of Cable: 105°C 220°F); of Handle: 105°C (220°F)
|
Temperature Accessories
|
|
|
Fluke 1550C Insulation Resistance Tester 5 kV
|
|
Test voltages to up 10 kV
CAT III 1000 V, CAT IV 600 V safety rating
Warning function alert for increased user safety
Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
Up to 99 memory locations
Over 750 tests between battery charges
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI)
Guard system eliminates the effect of surface leakage current on high-resistance measurements
Large digital/analog LCD
Capacitance and... |
Insulation Testers
|
|